TESLA Radon Sensor "TSRS (UART)" and "TSRS2 (RS485 - MODBUS)"
Intelligent detectors of radon concentration with simple serial interfaces UART, RS485 - MODBUS and RELAY for easy implemention into third party system. Suitable for integration into smart buildings, industrial systems and systems of air quality. Connection of probe is always by 4 - wires, 2 wires are for serial half-duplex data or for relay and 2 wires for DC powering. Coupled with sensors are delivered descriptions of interfaces and protocols for easy development and implementation of processor program. Current values of radon concentration, temperature and humidity are possible to read from sensors and also set limit for switching of alarm relay. Also is possible to download time records of radon concentration and energy spectrum from sensor internal memory.
Radon Sensor TSRS
TSRS sensor has alarm RELAY and wired serial interface UART. RELAY is design for remote alarm signalization of crossing radon limit over 4-wires cable (severel 100 meters). UART interface is design for direct connection with processor unit for short distance (severel meters) over 4 –wires cable too. Powering from +5VDC to +12VDC.
Radon Sensor TSRS2
TSRS2 sensor with wired serial interface RS485 is design for bus connection of more sensors with processor unit for long distance (severel 100 meters). Powering is in range +7VDC to +15VDC. Communication type and rate is possible to set by external switches as well as bus address of device.
Technical Data
Average measurement sensitivity |
0,25 imp/hod/Bq.m-3 |
Measuring range |
MDA - 100 000 Bq/m3; |
Measurement uncertainty |
< 13% at 300 Bq/m3 per 1 hour; |
Measuring chamber capacity |
0,176 dm3 |
Response rate |
< 30 minutes (RaA); < 3 hours (RaA + RaC) |
Measuring algorithm |
quicker, less sensitive (calculated from RaA) |
Radon concentration results display |
short-term (1 hour moving average) |
Measuring relative humidity range |
10 - 90 % |
Measuring temperature range |
-20 to +60 °C |
Serial interface |
UART, RS485-MODBUS |
Switching load of alarm relay |
250W DC/ 500W AC |
Records saving interval |
1- 255 minutes, default 1 hour |
Results memory capacity in probe |
4096 |
Powering |
5-12VDC/max. 5mA (UART); 7-15VDC/max. 5mA (RS485) |
Dimension |
Ø 80 x 175 mm |
Scope of Delivery
- TSRS / TSRS2 Radon Sensor
- TSRS: 2 opposite cable connectors for sensor connector
- TSRS2: Opposite cable connector into sensor connector
- Install cover
- Install holder of probe
- Operation Manual
There are no reviews yet.