Tesla TSR4 Radon Probe with WLAN and USB

Item number: TSR4x

starting from 866,59 €

including 16% VAT. , no shipping costs

Version

There are variations of this item. Please select the variation you wish.


Description

TSR4 for continuous measurement of radon concentrations in buildings

The portable probe base is a measuring chamber with a semiconductor photodetector. Radon enters the chamber by diffusion through the input filter on the underside of the probe. The probe measures autonomously and continuously. It processes the results in an interval of 4 minutes and counts the short-term moving average of the radon concentration (1 hour moving average - average of 15 4-minute process intervals). The device also counts the long-term moving average radon concentration (24-hour moving average).

Data storage and transmission

The probe stores time records of these radon concentration values including humidity and temperature values in its internal memory (typically at 1 hour intervals). In addition, the time recording values of the energy spectrum measurement (typically at 12 hour intervals) are measured. The resulting values can be downloaded continuously during the measurement or at the end of the measurement. The radon probe data can be transferred directly to a PC via the USB interface or wirelessly via antenna and central unit. The central unit is not included with TSR3 and is sold and delivered separately.

Positioning

The probe can be positioned anywhere, but generally it is placed on the ground for measurement. Do not cover the bottom of the probe.

Versions


Compared to the TSR4 you get a screen with the TSR4D. This enables a quick overview of the measured values.

Technical product information

Average measurement sensitivity

0,25 count/hour/Bq.m-3

(method RaA+RaC; 15°C ÷ 30°C; rel. hum. 20% ÷ 40%)

Measuring range

MDA - 100 000 Bq/m3; MDA = 100 Bq/m3 per 1 hour or 20 Bq/m3 per 24 hours

Measurement uncertainty

< 13% at 300 Bq/m3 per 1 hour; < 3% at 300 Bq/m3 per 24 hours

Measuring chamber capacity

0,176 dm3

Response rate

< 30 minutes (RaA); < 3 hours (RaA + RaC)

Radon records

calculated from RaA (quicker, less sensitive)

calculated form RaA + RaC (slower, more sensitive)

 

Measuring relative humidity range

10 - 90 %

Measuring temperature range

-20 to + 60 °C

Radio interface

868MHz

Max number of measuring network elements

16

Probe to terminal unit distance (RF range)

depends on number of walls and building material, up to 600 m in open space

Possibility of using repeater for RF range extending

yes

Results reading interval (from probe)

240-65535 sec (4 min - 18.2 hours)

Records saving interval (probe)

1- 255 minutes, default 1 hour

Results memory capacity in probe

4096 (150 days of 1 hours records)

Powering

internal rechargeble accumulator; charging via USB

Accu life after full charging

>1 year

Current radon concentration results

short-term (0,5 hour running average from RaA)

long-term (24 hours running average from RaA + RaC)

 

Dimension

Ø 80 x 175 mm

 

Radon probe variants

Probe Type

Connection

DisplayLarger StorageVentilation Triggering

TSR4

USB

 

WLAN 868 MHz

  

x

TSR4D

USB

 

WLAN 868 MHz

x

 

x

TSR4M

USB

   

x

 

TSR4DM

USB

  

x

x

 

TSR4S

USB

SIGFOX

GPS

   

TSRE1

Ethernet

MODBUS TCP/IP

Wi-Fi

 

x

 

TSRS

UART

 

RELAY

  

x

TSRS2

RS-485

 

MODBUS RTU

  

PDF

Type approval certificate

Ratings

Average product review

Write your first review and help others with their purchase decision: