Hauff-Technik | Multibranch service entrance for buildings without basement MSH Basic FUBO BHP x metre

Item number: 34-5xx

starting from 882,85 Dollar

including 19% VAT. , no shipping costs

Tube length

There are variations of this item. Please select the variation you wish.


Description

4-branch service entrances for buildings without basement

You are building a new house and need a radon-proof house entry for electricity, water, gas and media lines? Then the 4-branch service entrances for buildings without basements from Hauff-Technik is exactly the right choice! Depending on your circumstances, you can choose between 3, 6, 10 or 15 metres of hose length.

 

All the advantages of the multibranch service entrance at a glance

  • Multibranch service entrances for 4 separate supply lines in one component: gas, water, electricity and communication
  • Waterproof up to 1 bar in accordance with DIN 18322
  • Radon-tight according to DIN 18322
  • Gas-tight up to 1 bar according to DIN 18322
  • Precisely fitting installation in the floor slab
  • Pipeline hoses in various lengths with bending radius
  • Package incl. all necessary components
  • Height-adjustable structural shell
  • Empty pipes possible for later use
  • Continuous protective pipe connection up to the main supply pipes at the property boundary
  • Tests/standards: DVGW VP 601
  • Hose length: 3, 6, 10 or 15 metres

 

Scope of application

  • DIN 18533 W1.1-E
  • WU-concrete stress class 1
  • WU concrete stress class 2

 

Scope of delivery of the multibranch service entrance

  • Basic body for 4 sections
  • Height-adjustable installation device including water stop flange
  • 4 pieces of spiral hose 14078 including casing pipe and fitted 3-ribbed gaskets
  • Seal insert MSH Basic MBK R4
  • Sparity sealing element drinking water SDW 1x32/40/50
  • Sparity sealing element  electricity SDE 1x26-29/36-39/43-46/48-51
  • Sparity sealing element communication SDK 1x13-21+3x7-13+1x5-13
  • Gas installation set Schuck+RMA incl. blanking seal MBHP DN25 D0
  • 2 pcs. sleeve plugs MS78U 1x24-52 for electrical and water trades
  • 1 sleeve plug MS78K 1x13-21+3x7-13+1x5-12 for the communication trade
  • Universal gas termination plugs ABG63/70/78 1x32/40/50
  • 1 piece sleeve plug MS78 D0 for blind sealing
  • 1 tube lubricant

PDF

Hauff Technik | Multi-section house entry MSH Basic FUBO BHP Manual DE & EN

Illustrated installation manual for the multi-section house entry MSH Basic FUBO BHP for buildings without basement by Hauff Technik in German and English

PDF
Hauff Technik | Multi-section house entry MSH Basic FUBO BHP Manual DE & EN

Hauff Technik | Multi-section house entry MSH Basic FUBO BHP Flyer EN

The product flyer for the multi-section house entry MSH Basic FUBO BHP for buildings without basement by Hauff Technik in German

PDF
Hauff Technik | Multi-section house entry MSH Basic FUBO BHP Flyer EN

Hauff Technik | Multi-section house entry MSH Basic FUBO BHP Dimension DE

Dimensions of the multi-section house entry MSH Basic FUBO BHP for buildings without basement by Hauff Technik in German

PDF
Hauff Technik | Multi-section house entry MSH Basic FUBO BHP Dimension DE

Hauff Technik | Multi-section house entry MSH Basic FUBO BHP Data Sheet EN

Technical Data Sheet for Multi-section house entry MSH Basic FUBO BHP for buildings without basement from Hauff Technik in German

PDF
Hauff Technik | Multi-section house entry MSH Basic FUBO BHP Data Sheet EN

Ratings

Average product review